QGM350-01 |
0.35mL-1mm-Bonded |
350 μL Semi-Micro Cuvette, 1 mm Width. Clear Walls. Bonded / Glued, for Aqueous / Protein Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 350 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-02 |
0.35mL-1mm-Fused |
350 μL Semi-Micro Cuvette, 1 mm Width. Clear Walls. Fused, Resistant to Most Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 350 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-03 |
0.35mL-1mm-Molded |
350 μL Semi-Micro Cuvette, 1 mm Width. Clear Walls. Molded, Resistant to Corrosive and Organic Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 350 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-04 |
0.7mL-2mm-Bonded |
700 μL Semi-Micro Cuvette, 2 mm Width. Clear Walls. Bonded / Glued, for Aqueous / Protein Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 700 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-05 |
0.7mL-2mm-Fused |
700 μL Semi-Micro Cuvette, 2 mm Width. Clear Walls. Fused, Resistant to Most Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 700 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-06 |
0.7mL-2mm-Molded |
700 μL Semi-Micro Cuvette, 2 mm Width. Clear Walls. Molded, Resistant to Corrosive and Organic Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 700 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-07 |
1.05mL-3mm-Bonded |
1,050 μL Semi-Micro Cuvette, 3 mm Width. Clear Walls. Bonded / Glued, for Aqueous / Protein Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,050 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-08 |
1.05mL-3mm-Fused |
1,050 μL Semi-Micro Cuvette, 3 mm Width. Clear Walls. Fused, Resistant to Most Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,050 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-09 |
1.05mL-3mm-Molded |
1,050 μL Semi-Micro Cuvette, 3 mm Width. Clear Walls. Molded, Resistant to Corrosive and Organic Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,050 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-10 |
1.4mL-4mm-Bonded |
1,400 μL Semi-Micro Cuvette, 4 mm Width. Clear Walls. Bonded / Glued, for Aqueous / Protein Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,400 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-11 |
1.4mL-4mm-Fused |
1,400 μL Semi-Micro Cuvette, 4 mm Width. Clear Walls. Fused, Resistant to Most Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,400 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-12 |
1.4mL-4mm-Molded |
1,400 μL Semi-Micro Cuvette, 4 mm Width. Clear Walls. Molded, Resistant to Corrosive and Organic Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,400 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-13 |
1.75mL-5mm-Bonded |
1,750 μL Semi-Micro Cuvette, 5 mm Width. Clear Walls. Bonded / Glued, for Aqueous / Protein Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,750 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-14 |
1.75mL-5mm-Fused |
1,750 μL Semi-Micro Cuvette, 5 mm Width. Clear Walls. Fused, Resistant to Most Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,750 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-15 |
1.75mL-5mm-Molded |
1,750 μL Semi-Micro Cuvette, 5 mm Width. Clear Walls. Molded, Resistant to Corrosive and Organic Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,750 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-16 |
20uL-8.5mm-Bonded-Black |
20 μL Cuvette, Z dim: 8.5 mm. Lid Included. Bonded / Glued, for Aqueous Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 20 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-17 |
50uL-15mm-Bonded-Black |
50 μL Cuvette, Z dim: 15 mm. Lid Included. Bonded / Glued, for Aqueous Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 50 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-18 |
100uL-15mm-Bonded-Black |
100 μL Cuvette, Z dim: 15 mm. Lid Included. Bonded / Glued, for Aqueous Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 100 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-19 |
50uL-15mm-Black |
50 μL Cuvette, Z dim: 15 mm. Lid Included. Bonded / Glued, for Aqueous Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 50 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-20 |
100uL-15mm-Black |
100 μL Cuvette, Z dim: 15 mm. Lid Included. Bonded / Glued, for Aqueous Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 100 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-21 |
200uL-15mm-Bonded-Black |
200 μL Cuvette, Z dim: 15 mm. Lid Included. Bonded / Glued, for Aqueous Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 200 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-22 |
300uL-15mm-Bonded-Black |
300 μL Cuvette, Z dim: 15 mm. Lid Included. Bonded / Glued, for Aqueous Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 300 μL, Detection Method: Photometric, UV / Vis Spectroscopy |
QGM350-23 |
10mm-Rack-16-Positions |
Plastic Rack for 12.5 x 12.5 mm Cuvette, 16 Positions |