| QGM350-01 | 0.35mL-1mm-Bonded | 350 μL Semi-Micro Cuvette, 1 mm Width. Clear Walls. Bonded / Glued, for Aqueous / Protein Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 350 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-02 | 0.35mL-1mm-Fused | 350 μL Semi-Micro Cuvette, 1 mm Width. Clear Walls. Fused, Resistant to Most Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 350 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-03 | 0.35mL-1mm-Molded | 350 μL Semi-Micro Cuvette, 1 mm Width. Clear Walls. Molded, Resistant to Corrosive and Organic Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 350 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-04 | 0.7mL-2mm-Bonded | 700 μL Semi-Micro Cuvette, 2 mm Width. Clear Walls. Bonded / Glued, for Aqueous / Protein Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 700 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-05 | 0.7mL-2mm-Fused | 700 μL Semi-Micro Cuvette, 2 mm Width. Clear Walls. Fused, Resistant to Most Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 700 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-06 | 0.7mL-2mm-Molded | 700 μL Semi-Micro Cuvette, 2 mm Width. Clear Walls. Molded, Resistant to Corrosive and Organic Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 700 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-07 | 1.05mL-3mm-Bonded | 1,050 μL Semi-Micro Cuvette, 3 mm Width. Clear Walls. Bonded / Glued, for Aqueous / Protein Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,050 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-08 | 1.05mL-3mm-Fused | 1,050 μL Semi-Micro Cuvette, 3 mm Width. Clear Walls. Fused, Resistant to Most Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,050 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-09 | 1.05mL-3mm-Molded | 1,050 μL Semi-Micro Cuvette, 3 mm Width. Clear Walls. Molded, Resistant to Corrosive and Organic Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,050 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-10 | 1.4mL-4mm-Bonded | 1,400 μL Semi-Micro Cuvette, 4 mm Width. Clear Walls. Bonded / Glued, for Aqueous / Protein Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,400 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-11 | 1.4mL-4mm-Fused | 1,400 μL Semi-Micro Cuvette, 4 mm Width. Clear Walls. Fused, Resistant to Most Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,400 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-12 | 1.4mL-4mm-Molded | 1,400 μL Semi-Micro Cuvette, 4 mm Width. Clear Walls. Molded, Resistant to Corrosive and Organic Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,400 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-13 | 1.75mL-5mm-Bonded | 1,750 μL Semi-Micro Cuvette, 5 mm Width. Clear Walls. Bonded / Glued, for Aqueous / Protein Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,750 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-14 | 1.75mL-5mm-Fused | 1,750 μL Semi-Micro Cuvette, 5 mm Width. Clear Walls. Fused, Resistant to Most Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,750 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-15 | 1.75mL-5mm-Molded | 1,750 μL Semi-Micro Cuvette, 5 mm Width. Clear Walls. Molded, Resistant to Corrosive and Organic Chemicals. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 1,750 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-16 | 20uL-8.5mm-Bonded-Black | 20 μL Cuvette, Z dim: 8.5 mm. Lid Included. Bonded / Glued, for Aqueous Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 20 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-17 | 50uL-15mm-Bonded-Black | 50 μL Cuvette, Z dim: 15 mm. Lid Included. Bonded / Glued, for Aqueous Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 50 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-18 | 100uL-15mm-Bonded-Black | 100 μL Cuvette, Z dim: 15 mm. Lid Included. Bonded / Glued, for Aqueous Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 100 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-19 | 50uL-15mm-Black | 50 μL Cuvette, Z dim: 15 mm. Lid Included. Bonded / Glued, for Aqueous Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 50 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-20 | 100uL-15mm-Black | 100 μL Cuvette, Z dim: 15 mm. Lid Included. Bonded / Glued, for Aqueous Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 100 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-21 | 200uL-15mm-Bonded-Black | 200 μL Cuvette, Z dim: 15 mm. Lid Included. Bonded / Glued, for Aqueous Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 200 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-22 | 300uL-15mm-Bonded-Black | 300 μL Cuvette, Z dim: 15 mm. Lid Included. Bonded / Glued, for Aqueous Samples Only. H x W x D: 45 x 12.5 x 12.5 mm, Pathlength: 10 mm, 2 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range. Chamber Volume 300 μL, Detection Method: Photometric, UV / Vis Spectroscopy | 
| QGM350-23 | 10mm-Rack-16-Positions | Plastic Rack for 12.5 x 12.5 mm Cuvette, 16 Positions | 
 
There are no reviews yet.