0.5 mm Cuvette with PTFE Screw Cap, 0.17 mL, QGS05T


Looking for the perfect cuvette for absorption applications? Our 0.17mL, 0.5mm Pathlength Cuvettes with Screw Cap is just what you need! These short path-length cuvettes are designed to give you maximum accuracy and ease of use. Whether you’re working in the lab or in the field, our cuvettes provide the ideal solution for your needs.

$13.00$418.00

A minimum of 2 units is required to checkout. Worldwide shipping.

When precise measurements and accuracy are important, the 0.5 mm Cuvette with PTFE Screw Cap, 0.17mL, QGS05T is the ideal product to measure liquids. This high quality molded cuvette offers resistance to organic and corrosive chemicals and is capable of measuring spectral ranges between 200-2,500 nm.

The easy-to-use design features a 55 x 12.5 x 3 mm body, with two polished windows and a path length of 0.5mm. It also has a chamber volume of 175 μL for efficient detection using photometry methods. Make sure to get accurate results every time with this reliable cuvette that comes with a PTFE screw cap for your convenience. Available as 1 pc/ea, invest in lasting quality today!

Why cuvettes with 0.5mm short path length?

Cuvettes with a 0.5 mm short path length are highly sought after in the realm of laboratory analysis due to their unique and valuable features. These specialized cuvettes provide researchers with a powerful tool for tackling challenging analytical tasks and achieving superior results. By significantly reducing the path length through which light passes in the sample, cuvettes with a 0.5 mm path length offer exceptional sensitivity and precision, making them the preferred choice for applications that demand the highest level of accuracy and detection capabilities. With their ability to amplify weak signals and accommodate low-concentration samples, these cuvettes open up new avenues for scientific exploration and enable researchers to unravel intricate details that may have previously eluded their grasp. Embracing the advantages offered by cuvettes with a 0.5 mm path length can revolutionize your analytical processes and empower you to push the boundaries of scientific understanding.

  • Increased Sensitivity: The shorter path length allows for a higher optical density or absorbance, making it ideal for samples with low concentrations or weak signals. By reducing the distance the light travels through the sample, cuvettes with a 0.5 mm path length enhance the detection sensitivity, enabling accurate measurements even with limited sample volumes.
  • Time-Saving Analysis: Cuvettes with a 0.5 mm path length require smaller sample volumes compared to longer path lengths. This feature is advantageous when working with limited or precious samples, as it minimizes the amount of sample needed for analysis. Additionally, reduced sample volumes can lead to faster analysis times, improving overall workflow efficiency.
  • Dilution Avoidance: Some samples may be sensitive to dilution or may have limited availability, necessitating the use of smaller sample volumes. Cuvettes with a 0.5 mm path length allow for precise analysis without the need for extensive dilution, preserving sample integrity and minimizing potential errors associated with dilution steps.
  • Microscale Applications: Cuvettes with a 0.5 mm path length are particularly suitable for microscale applications, such as microfluidics, microreactors, or microspectroscopy. These cuvettes can accommodate the smaller dimensions and volumes associated with microscale experiments, providing accurate measurements within the confined space.
  • Increased Resolution: The shorter path length of 0.5 mm enhances the resolution of the optical measurements, enabling the detection of fine spectral features or subtle changes in absorbance. This enhanced resolution is beneficial for applications that require detailed analysis of spectral characteristics or the differentiation of closely related compounds.

Overall, cuvettes with a 0.5 mm short path length offer enhanced sensitivity, time-saving analysis, avoidance of dilution, suitability for microscale applications, and increased resolution. Consider utilizing these cuvettes when working with low-concentration samples, limited volumes, or applications that demand high sensitivity and precision.

01

Our Fabrication Types

Most types of Aireka Scientific quartz cuvettes including customized cells are available with the following 3 types of fabrication standards:

0123
*Molded*Fused*Bonded / Glued
UV vis ( 190- 2500 nm)YesYesYes
Transmission Matched YesYesYes
Transmission > 80%YesYesYes
Resistant to Acids and Bases (except hydrofluoric acid)YesYesNo
Resistant to Organic SolventsYesYesNo
Usable upto 500°C (932°F)YesYesNo
Usable upto 1200°C (2192°F)YesNoNo
0 Variations ReadingOn RequestNoNo
FabricationMoldedAssembled with Quartz PowderAssembled with Glue
AdhesivesNoNoYes
StorageShort Term StorageClean After UseClean After Use
Available MaterialES Quartz Material
NoteMolded and fused cuvettes and cells are assembled by direct fusion without the use of adhesives throughout the production process. This guarantees resistance against corrosive chemicals and high temperature. Each quartz cuvette and cell has excellent transmission from 190nm to 2500nm.
0

UV Quartz Glass Cuvettes

Most of our quartz cuvettes are made from ES quartz material, absorption onset occurs below 190 nm and there are no absorption bands situated between 190 nm and 250 nm. Exceptionally high transmittance across the UVB, UVA, visible spectrum, and near IR. The transmission spectra for our UV quartz cells can be seen below. When working in the IR spectra, especially for wavelengths greater than 2000 nm, we recommend IR Quartz Glass Cuvettes instead, as they offer high transmission for these wavelengths.

IR Quartz Glass Cuvettes

Made from IR quartz material, absorption onset occurs below 260 nm with exceptionally high transmission across UVB, UVA, visible, near IR, and notably short IR. Transmission drops significantly in the mid-IR, and at 4200 nm there is complete absorption.

Why Aireka Scientific Cuvettes and Cells?

Aireka Scientific Co Limited is world-renowned as the producer of premium quartz cuvettes. Over twenty years of experience manufacturing quartz cuvettes ensures that every cuvette is manufactured to the most exacting standards for reproducible results.

  • Spectrophotometry cuvettes - Most spectrophotometry applications in the visible and UV ranges benefit from Aireka Scientific spectrophotometry cuvettes. Our cuvettes made of ES quartz material deliver precise and reliable readings even at wavelengths as low as 190 nm. The stock cuvettes are compatible with most spectrophotometers and photometers with standard 0.2 - 100 mm path lengths.
  • Fluorimetry cuvettes - Aireka Scientific brings two decades of experience molding high-quality fluorescence cuvettes to new four-sided clear cuvettes for fluorimetry. Available in standard quartz material with ultra-low auto-fluorescence for the highest precision measurements.
  • Protective packaging - Our cuvettes are in dust-free, low scratching-expanded polystyrene packaging. This ensures that premium cuvettes arrive in the laboratory in the same pristine condition they were in at the factory, with optical quality windows and free of contaminants. 
  • Volumes for most purposes - Our cuvettes are available in a variety of ranges from micro to macro semi-micro sizes to respond to the needs of most scientific applications. We can also customize sample volume to deliver consistent, accurate findings.
  • Perform consistently - The Cuvettes are constructed from high-quality fused quartz materials and are grouped by manufacturing mold cavities to ensure the lowest fluctuation in extinction coefficient.
  • Customization - Custom cuvettes and cells are encouraged and available upon request; mechanical drawings with specifications and tolerances are prerequisites. Awesome pricing and flexibility on small quantities. 

  •  
01

Frequently Asked Questions


 

Do you ship to my country?

We ship our products worldwide. We ship orders using a tracked courier service as standard (usually FedEx, sometimes DHL) although we are also happy to be flexible if your University or Institution has specific requirements. Other methods are available for a wide variety of countries.

Please note that customs restrictions can vary between countries. If you are uncertain about shipment to your country, please contact us for advice.

What if I want to return or cancel my order?

We hope you love your order, but if you wish to return any items ordered, please notify us within 21 days of receiving the goods. Please ensure that they are returned as new, undamaged, free of contamination and in the original packaging.

Please inspect all orders on arrival to ensure your products are in good condition.

What happens if the item is broken?

If an item breaks due to the manufacturer's error then we will replace the cuvette free of charge, with no costs passed on to our customers.

Any damage to an item that is not caused by a manufacturer's error is not eligible for a free replacement. This would include items that are mishandled, dropped, scratched, etc.

How do I place an Order?

For your convenience, we offer a number of ways of placing an order.

  1. Order online through this shop
  2. E-mail us your purchase order at sales@airekasci.com
  3. If you have custom designs, please contact us


To the best of our knowledge, the information provided here is accurate. However, Aireka Scientific assumes no liability for the accuracy of this page. The values provided are typical at the time of manufacture and may vary over time and from batch to batch. All products are for laboratory and research and development use only, and may not be used for any other purpose including health care, pharmaceuticals, cosmetics, food, or commercial applications.

Weight 50 g
Options

0.5mm-Macro-Thread-Molded, Cap-with-Center-Hole

QGS05T-01 0.5mm-Macro-Thread-Molded 0.5 mm, Macro PTFE Screw Cap Included, Molded, High Quality, Resistant to Organic and Corrosive Chemicals. H x W x D: 55 x 12.5 x 3 mm, Pathlength: 0.5 mm, 2 Polished Windows, Material: Quartz, 200 – 2,500 nm Spectral Range, Chamber Volume 175 μL, Detection Method: Photometric
QGS05T-02 Cap-with-Center-Hole PTFE Screw Cap with 2 mm Center Hole, Liner Included for QGS05T-01GS05F

Based on 0 reviews

0.0 overall
0
0
0
0
0

Only logged in customers who have purchased this product may leave a review.

There are no reviews yet.