When precise measurements and accuracy are important, the 0.5 mm Cuvette with PTFE Screw Cap, 0.17mL, QGS05T is the ideal product to measure liquids. This high quality molded cuvette offers resistance to organic and corrosive chemicals and is capable of measuring spectral ranges between 200-2,500 nm.
The easy-to-use design features a 55 x 12.5 x 3 mm body, with two polished windows and a path length of 0.5mm. It also has a chamber volume of 175 μL for efficient detection using photometry methods. Make sure to get accurate results every time with this reliable cuvette that comes with a PTFE screw cap for your convenience. Available as 1 pc/ea, invest in lasting quality today!
Why cuvettes with 0.5mm short path length?
Cuvettes with a 0.5 mm short path length are highly sought after in the realm of laboratory analysis due to their unique and valuable features. These specialized cuvettes provide researchers with a powerful tool for tackling challenging analytical tasks and achieving superior results. By significantly reducing the path length through which light passes in the sample, cuvettes with a 0.5 mm path length offer exceptional sensitivity and precision, making them the preferred choice for applications that demand the highest level of accuracy and detection capabilities. With their ability to amplify weak signals and accommodate low-concentration samples, these cuvettes open up new avenues for scientific exploration and enable researchers to unravel intricate details that may have previously eluded their grasp. Embracing the advantages offered by cuvettes with a 0.5 mm path length can revolutionize your analytical processes and empower you to push the boundaries of scientific understanding.
- Increased Sensitivity: The shorter path length allows for a higher optical density or absorbance, making it ideal for samples with low concentrations or weak signals. By reducing the distance the light travels through the sample, cuvettes with a 0.5 mm path length enhance the detection sensitivity, enabling accurate measurements even with limited sample volumes.
- Time-Saving Analysis: Cuvettes with a 0.5 mm path length require smaller sample volumes compared to longer path lengths. This feature is advantageous when working with limited or precious samples, as it minimizes the amount of sample needed for analysis. Additionally, reduced sample volumes can lead to faster analysis times, improving overall workflow efficiency.
- Dilution Avoidance: Some samples may be sensitive to dilution or may have limited availability, necessitating the use of smaller sample volumes. Cuvettes with a 0.5 mm path length allow for precise analysis without the need for extensive dilution, preserving sample integrity and minimizing potential errors associated with dilution steps.
- Microscale Applications: Cuvettes with a 0.5 mm path length are particularly suitable for microscale applications, such as microfluidics, microreactors, or microspectroscopy. These cuvettes can accommodate the smaller dimensions and volumes associated with microscale experiments, providing accurate measurements within the confined space.
- Increased Resolution: The shorter path length of 0.5 mm enhances the resolution of the optical measurements, enabling the detection of fine spectral features or subtle changes in absorbance. This enhanced resolution is beneficial for applications that require detailed analysis of spectral characteristics or the differentiation of closely related compounds.
Overall, cuvettes with a 0.5 mm short path length offer enhanced sensitivity, time-saving analysis, avoidance of dilution, suitability for microscale applications, and increased resolution. Consider utilizing these cuvettes when working with low-concentration samples, limited volumes, or applications that demand high sensitivity and precision.
To the best of our knowledge, the information provided here is accurate. However, Aireka Scientific assumes no liability for the accuracy of this page. The values provided are typical at the time of manufacture and may vary over time and from batch to batch. All products are for laboratory and research and development use only, and may not be used for any other purpose including health care, pharmaceuticals, cosmetics, food, or commercial applications.
0 1 2 3
*Molded *Fused *Bonded / Glued
UV vis ( 190- 2500 nm) Yes Yes Yes
Transmission Matched Yes Yes Yes
Transmission > 80% Yes Yes Yes
Resistant to Acids and Bases (except hydrofluoric acid) Yes Yes No
Resistant to Organic Solvents Yes Yes No
Usable upto 500°C (932°F) Yes Yes No
Usable upto 1200°C (2192°F) Yes No No
0 Variations Reading On Request No No
Fabrication Molded Assembled with Quartz Powder Assembled with Glue
Adhesives No No Yes
Storage Short Term Storage Clean After Use Clean After Use
Available Material ES Quartz Material
Note Molded and fused cuvettes and cells are assembled by direct fusion without the use of adhesives throughout the production process. This guarantees resistance against corrosive chemicals and high temperature. Each quartz cuvette and cell has excellent transmission from 190nm to 2500nm.
There are no reviews yet.