1 / 2 mm Custom Narrow Width Cuvette with 4 Windows, QGC070


Our custom 1 x 10 mm and 2 x 10 mm pathlength cuvettes are designed to meet the specific needs of fluorescence experiments, with an ideal volume of 0.55 / 1.1 mL. These cuvettes will ensure that your experiment is performed with the utmost precision and accuracy.

$278.00

A minimum of 2 units is required to checkout. Worldwide shipping.

The QGC070 – a 1/2 mm custom narrow-width cuvette with 4 polished windows – offers a range of features specifically designed to meet the needs of research and lab professionals. Let’s explore these features in detail:

  • Optimal Biochemical Protection: The QGC070 cuvette provides an ideal solution for safeguarding biochemical samples during analysis. Its quartz construction ensures excellent resistance to most chemicals, protecting your valuable samples from any potential damage or contamination.
  • Effective Light Transmission: With its 4 polished windows, this cuvette maximizes light transmission for fluorescence detection. The polished surfaces enable precise and accurate readings, enhancing the reliability of your measurements.
  • Versatile Path Length and Spectral Range: The QGC070 cuvette offers a path length of 1-2 mm, providing flexibility for a wide range of applications. It covers the 200 – 2,500 nm spectral range, making it suitable for diverse experiments such as protein analysis, enzyme kinetics, absorbance measurements, and nucleic acid/oligonucleotide assays.
  • Ample Chamber Volume: With a chamber volume ranging from 550-1100 μL, this cuvette accommodates an ample sample size for thorough analysis. You can perform experiments without limitations, ensuring accurate and comprehensive results.
  • Compact and Durable Design: The QGC070 cuvette features compact dimensions of 70 x 12.5 x 12.5 mm, making it compatible with most spectrophotometers. 

Embrace the precision and efficiency of the QGC070 1/2 mm custom narrow-width cuvette with 4 polished windows. Its exceptional biochemical protection, effective light transmission, versatile path length, and ample chamber volume make it an indispensable tool for your research endeavors. Don’t delay your scientific exploration—order now to unlock the full potential of accurate and reliable results!


Z dimension of Sub-Micro Cuvettes is available 8.5 / 15 / 20 mm for customization on request. Please email us: sales@airekasci.com.


01

Our Fabrication Types

Most types of Aireka Scientific quartz cuvettes including customized cells are available with the following 3 types of fabrication standards:


0123
*Molded*Fused*Bonded / Glued
UV vis ( 190- 2500 nm)YesYesYes
Transmission Matched YesYesYes
Transmission > 80%YesYesYes
Resistant to Acids and Bases (except hydrofluoric acid)YesYesNo
Resistant to Organic SolventsYesYesNo
Usable upto 500°C (932°F)YesYesNo
Usable upto 1200°C (2192°F)YesNoNo
0 Variations ReadingOn RequestNoNo
FabricationMoldedAssembled with Quartz PowderAssembled with Glue
AdhesivesNoNoYes
StorageShort Term StorageClean After UseClean After Use
Available MaterialES Quartz Material
NoteMolded and fused cuvettes and cells are assembled by direct fusion without the use of adhesives throughout the production process. This guarantees resistance against corrosive chemicals and high temperature. Each quartz cuvette and cell has excellent transmission from 190nm to 2500nm.
0

UV Quartz Glass Cuvettes

Most of our quartz cuvettes are made from ES quartz material, absorption onset occurs below 190 nm and there are no absorption bands situated between 190 nm and 250 nm. Exceptionally high transmittance across the UVB, UVA, visible spectrum, and near IR. The transmission spectra for our UV quartz cells can be seen below. When working in the IR spectra, especially for wavelengths greater than 2000 nm, we recommend IR Quartz Glass Cuvettes instead, as they offer high transmission for these wavelengths.

IR Quartz Glass Cuvettes

Made from IR quartz material, absorption onset occurs below 260 nm with exceptionally high transmission across UVB, UVA, visible, near IR, and notably short IR. Transmission drops significantly in the mid-IR, and at 4200 nm there is complete absorption.

Why Aireka Scientific Cuvettes and Cells?

Aireka Scientific Co Limited is world-renowned as the producer of premium quartz cuvettes. Over twenty years of experience manufacturing quartz cuvettes ensures that every cuvette is manufactured to the most exacting standards for reproducible results.

  • Spectrophotometry cuvettes - Most spectrophotometry applications in the visible and UV ranges benefit from Aireka Scientific spectrophotometry cuvettes. Our cuvettes made of ES quartz material deliver precise and reliable readings even at wavelengths as low as 190 nm. The stock cuvettes are compatible with most spectrophotometers and photometers with standard 0.2 - 100 mm path lengths.
  • Fluorimetry cuvettes - Aireka Scientific brings two decades of experience molding high-quality fluorescence cuvettes to new four-sided clear cuvettes for fluorimetry. Available in standard quartz material with ultra-low auto-fluorescence for the highest precision measurements.
  • Protective packaging - Our cuvettes are in dust-free, low scratching-expanded polystyrene packaging. This ensures that premium cuvettes arrive in the laboratory in the same pristine condition they were in at the factory, with optical quality windows and free of contaminants. 
  • Volumes for most purposes - Our cuvettes are available in a variety of ranges from micro to macro semi-micro sizes to respond to the needs of most scientific applications. We can also customize sample volume to deliver consistent, accurate findings.
  • Perform consistently - The Cuvettes are constructed from high-quality fused quartz materials and are grouped by manufacturing mold cavities to ensure the lowest fluctuation in extinction coefficient.
  • Customization - Custom cuvettes and cells are encouraged and available upon request; mechanical drawings with specifications and tolerances are prerequisites. Awesome pricing and flexibility on small quantities. 

  •  
01

Frequently Asked Questions


 

Do you ship to my country?

We ship our products worldwide. We ship orders using a tracked courier service as standard (usually FedEx, sometimes DHL) although we are also happy to be flexible if your University or Institution has specific requirements. Other methods are available for a wide variety of countries.

Please note that customs restrictions can vary between countries. If you are uncertain about shipment to your country, please contact us for advice.

What if I want to return or cancel my order?

We hope you love your order, but if you wish to return any items ordered, please notify us within 21 days of receiving the goods. Please ensure that they are returned as new, undamaged, free of contamination and in the original packaging.

Please inspect all orders on arrival to ensure your products are in good condition.

What happens if the item is broken?

If an item breaks due to the manufacturer's error then we will replace the cuvette free of charge, with no costs passed on to our customers.

Any damage to an item that is not caused by a manufacturer's error is not eligible for a free replacement. This would include items that are mishandled, dropped, scratched, etc.

How do I place an Order?

For your convenience, we offer a number of ways of placing an order.

  1. Order online through this shop
  2. E-mail us your purchase order at sales@airekasci.com
  3. If you have custom designs, please contact us


To the best of our knowledge, the information provided here is accurate. However, Aireka Scientific assumes no liability for the accuracy of this page. The values provided are typical at the time of manufacture and may vary over time and from batch to batch. All products are for laboratory and research and development use only, and may not be used for any other purpose including health care, pharmaceuticals, cosmetics, food, or commercial applications.

Weight 80 g
Options

1-10mm-4-Windows-Fused, 2-10mm-4-Windows-Fused

QGC070-01 1-10mm-4-Windows-Fused 1 x 10 mm Custom Cuvette, Fused, Resistant to Most Chemicals. H x W x D: 70 x 12.5 x 12.5 mm, Pathlength: 1 x 10 mm, 4 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range, Chamber Volume 550 μL, Detection Method: Fluorometric
QGC070-02 2-10mm-4-Windows-Fused 2 x 10 mm Custom Cuvette, Fused, Resistant to Most Chemicals. H x W x D: 70 x 12.5 x 12.5 mm, Pathlength: 2 x 10 mm, 4 Polished Windows. Material: Quartz, 200 – 2,500 nm Spectral Range, Chamber Volume 1,100 μL, Detection Method: Fluorometric

Based on 0 reviews

0.0 overall
0
0
0
0
0

Only logged in customers who have purchased this product may leave a review.

There are no reviews yet.